KEDA KD999 Structural Silicone Glazing Sealant

KD999 is a single-component, neutral cure, room temperature vulcanizing (RTV) structural silicone sealant with excellent adhesion to glass, aluminum alloy, and other building materials. Widely used for structural bonding and sealing in glass curtain walls and metal construction projects, it delivers exceptional weather resistance and is suitable for long-term use in humid, hot, and marine salt spray environments. With a service life of up to 40 years under normal conditions, it provides reliable structural performance for demanding facade applications.

  • Structural Grade: Specifically designed for load-bearing structural glazing applications
  • Safe & Non-Corrosive: Neutral curing formula, non-corrosive to glass, aluminum alloy, and coatings
  • Exceptional Durability: 40-year service life under normal weather conditions
  • Superior Adhesion: Excellent bonding to most building materials, typically no primer required
  • Environmental Resistance: Suitable for humid, hot, and marine salt spray environments
  • Excellent Compatibility: Good compatibility with other neutral silicone sealants
  • High Performance: Maintains structural integrity under extreme conditions
Applocation
  • Structural bonding and sealing for glass curtain wall systems
  • Structural glazing for aluminum panel curtain walls
  • Glass skylight structural bonding
  • Metal structural engineering applications
  • Factory or on-site assembly of glass and metal materials
  • Two-sided structural glazing systems
  • Four-sided structural glazing systems
  • Other construction and industrial structural applications
Package
  • Cartridge Size: 590ml
  • Available Colors: Black, Gray (structural grade typically in dark colors), Customized
  • Packaging Type: Sausage pack/cartridge
  • Shelf Life: 12 months from production date (in sealed original container)
  • Storage Conditions: Store in cool, dry place below 27°C

Step 1: Surface Preparation (CRITICAL for structural applications)

  • All substrates must be thoroughly cleaned and free from contamination, dust, oil, grease, moisture, and loose particles
  • Clean glass with appropriate solvents and wipe dry
  • Clean aluminum with isopropanol or approved cleaner
  • Allow surfaces to dry completely before application
  • Conduct adhesion tests on actual substrates before production application

Step 2: Priming (if required)

  • Apply appropriate primer if specified by adhesion test results
  • Follow primer manufacturer’s instructions for application and flash-off time
  • Typically, no primer is required for glass and anodized aluminum

Step 3: Joint Design (Follow structural calculations)

  • Bite depth and width must be determined by structural engineer
  • Typical bite depth: 6-12mm depending on glass size and wind load
  • Ensure proper clearance and no three-sided adhesion
  • Use setting blocks and spacers as per design

Step 4: Application

  • Cut nozzle to match bite width requirements
  • Load cartridge into professional-grade caulking gun or power applicator
  • Apply sealant in a continuous, uniform bead
  • Ensure complete fill with no voids or air pockets
  • Work methodically to maintain quality

Step 5: Curing (CRITICAL)

  • Allow full cure before glass installation: minimum 7 days, typically 14-21 days
  • Protect from contamination, moisture, and stress during cure
  • Do not handle or install glass panels before full cure
  • Monitor environmental conditions throughout cure period

Additional information

Product Type

Single-component structural silicone sealant

Grade

Structural glazing grade

Cure System

Moisture cure (neutral)

Skin Formation Time

10-20 minutes (23°C, 50% RH)

Tack-Free Time

20-30 minutes (23°C, 50% RH)

Curing Speed

3-5 mm/24 hours

Application Temperature

+5°C to +40°C

Service Temperature

-50°C to +150°C

Service Life

40 years (under normal conditions)

Movement Capability

±25%

Hardness (Shore A)

35-50

Tensile Strength

≥1.2 MPa

Elongation at Break

≥300%

Tensile Modulus at 100%

0.8-1.2 MPa

Adhesion Strength

≥0.6 MPa (to glass, aluminum)

Limitation
  • NOT suitable for materials that exude oils, plasticizers, or solvents
  • NOT recommended for poorly ventilated spaces during cure
  • NOT suitable for surfaces in direct contact with food or potable water
  • NOT recommended for continuous water immersion
  • DO NOT apply when substrate temperature is below +4°C or above +50°C
  • NOT for use with certain plastics (conduct compatibility tests)
  • NOT paintable
  • ONLY use for structural applications if qualified through proper testing and engineering approval
Tips

CRITICAL – Structural Application Requirements:

  • Engineering Approval Required: This product must be specified by qualified structural engineer
  • Mandatory Testing: Conduct adhesion tests on all actual substrates before production use
  • Quality Control: Implement strict QC procedures for all structural glazing work
  • Certification: Ensure installers are trained and certified for structural glazing
  • Documentation: Maintain complete records of testing, installation conditions, and quality checks
  • Building Codes: Follow all local building codes and structural glazing standards

For Best Results:

  • Work only in controlled environmental conditions (temperature 15-30°C, humidity 30-70%)
  • Use professional-grade equipment for consistent bead application
  • Never compromise on surface preparation – this is critical for structural performance
  • Allow full cure time – do not rush structural installations
  • Coordinate with project engineer on all bite dimensions and glass loads
  • Consider environmental factors: wind loads, thermal cycling, seismic requirements

Environmental Suitability:

  • Excellent for coastal/marine environments with salt spray exposure
  • Performs well in hot, humid tropical climates
  • Maintains adhesion in freeze-thaw cycling conditions
  • UV-stable for long-term outdoor exposure

Storage & Handling:

  • Store in controlled environment
  • Rotate stock carefully – use oldest material first
  • Once opened, use immediately or within recommended timeframe
  • Protect from contamination and moisture

Safety:

  • Ensure adequate ventilation during application and cure
  • Wear appropriate PPE (gloves, safety glasses)
  • Follow all safety data sheet (SDS) recommendations