A documented ±25% movement capability describes extension and compression relative to a reference joint width. In a simplified example with a 12 mm installation width, 25% is 3 mm. That means 3 mm of opening and 3 mm of closing from that reference, considered separately. It does not mean the joint can move 25 mm or that 25% is the entire span from its narrowest to widest state.
Use that arithmetic to read a rating and screen a proposed joint. The project still needs an agreed movement estimate, actual installation widths and a sealant with evidence for the specified application. The numbers in this article are examples; they do not establish a product rating or an approved joint detail.
1. Start With Three Widths
Collect the reference width at installation and the expected minimum and maximum in service. Use values for the same joint location. For a first check, define the reference as the width when the sealant is installed and have the project team confirm how movement during cure and installation conditions are accounted for.
Keep the nominal drawing dimension separate from the measured opening. A drawing may call for 12 mm while individual bays are narrower or wider. Survey the intended bonding plane at representative positions and record the smallest and largest openings that matter. Measuring the visible gap at the surface can give a different number if the edges are beveled or the joint narrows deeper in.

Illustrative dry-fit mockup. Measure at the intended sealant location using the project’s inspection method; the photo supplies no measurement.
| Width | What it represents | Where to get it |
|---|---|---|
| Nominal width | Dimension shown on the drawing | Approved joint detail |
| Installation reference width | Width from which the movement is evaluated | Measured opening and agreed installation assumptions |
| Minimum service width | Narrowest expected opening at that location | Project movement assessment |
| Maximum service width | Widest expected opening at that location | Project movement assessment |
A measurement taken today tells you the current width. It does not tell you how far the joint will move later. Ask the responsible design team for opening and closing demand and any relevant movement along or out of the joint plane. Keep the temperature and condition associated with the survey so those measurements can be interpreted.
Ask what contributes to the expected movement. Adjacent materials may respond differently to temperature, and the assembly may also change with moisture, building movement or other project conditions. Record whether the widths are measured values, design estimates or limits taken from the approved detail. That distinction prevents a supplier from treating a single site reading as the full service range. Include the survey date, joint location and material temperatures when available, especially if some areas were measured in sun and others in shade.
2. Calculate Opening and Closing Separately
For a simple change in width, subtract the reference width from the widest expected opening to find extension. Subtract the narrowest expected opening from the reference width to find compression. Divide each change by the same reference width and multiply by 100 to express it as a percentage. Here, compression is shown as a positive magnitude in the calculations and with a minus sign when written as a directional rating.
Suppose a joint is installed at 12 mm and the project example gives service widths of 9.6 mm and 15 mm. The joint closes by 2.4 mm and opens by 3.0 mm. The movement demand is therefore 20% compression and 25% extension. The total change between the two service extremes is 5.4 mm, but that is not the extension from the installed position.

Illustrative arithmetic only. Both percentages use the 12 mm reference. This diagram does not specify sealant depth, backing or a product rating.
| Calculation | Example | Result |
|---|---|---|
| Opening from reference | 15.0 − 12.0 mm | 3.0 mm extension |
| Closing from reference | 12.0 − 9.6 mm | 2.4 mm compression |
| Opening demand | 3.0 ÷ 12.0 × 100 | 25% extension |
| Closing demand | 2.4 ÷ 12.0 × 100 | 20% compression |
| Full width span | 15.0 − 9.6 mm | 5.4 mm between extremes |
On this simplified arithmetic alone, a hypothetical ±25% rating covers the example’s closing demand and reaches its opening demand exactly. There is no opening allowance left for deviations in this example. A project review still has to account for tolerances, product geometry limits and other requirements. Do not turn equality in a screening calculation into a purchase approval.
3. Check What Changes Across the Installation
The same millimeters of movement can represent different percentages. If a second location is 10 mm wide at installation and the project separately confirms the same 3.0 mm opening and 2.4 mm closing demand there, the demands become 30% extension and 24% compression. The opening side now exceeds the hypothetical 25% capability. This example holds the relative movements constant to show the effect of width; on a real project, use the assessed movements for that location.
An installation that starts near one end of its service range can also have more travel in one direction than the other. Do not divide the full service span in half unless the reference width is actually at the midpoint. Ask which installation conditions were assumed, how wide or narrow the opening can be on site and whether movement during cure needs a separate check.
For long runs, record the width range by area rather than keeping one average. Note short tight sections, corners, transitions and areas where a different material meets the panel. If the openings fall outside the detail, flag those locations before sealing. The project team can then review the geometry or specify a suitable alternative instead of relying on the crew to compensate with more sealant.
Keep the width check separate from other directions of movement. A joint can also experience sliding along its length or displacement out of plane. The simple percentages above describe change in width. Combined movement, unusual geometry or a joint that has to retain a different assembly function requires a review of the actual detail.
On a repair job, photograph the existing seal before removing it. Note whether it has split through the bead, pulled away from one face or squeezed outward. Those patterns can guide the inspection, but they do not identify excess movement by themselves. Check adhesion, preparation and the old section alongside the movement assessment. Installing a product with a larger stated percentage leaves the underlying issue unresolved if the joint was actually failing at a contaminated or incompatible surface.
4. Read the Evidence Behind the Number
Request the technical documentation for the exact supplied grade. Check the stated movement limits, test method or classification and where the product is intended to be used. Some ratings are written with different opening and closing limits. Compare each direction with its corresponding requirement rather than choosing the larger number or averaging the two.
An elongation-at-break value answers a different question from movement capability under cycling. A tensile specimen can stretch a long way before it breaks without showing that a bonded joint will tolerate repeated opening and closing. ASTM C719 evaluates adhesion and cohesion of sealants under cyclic movement; ASTM C920 is a specification with product designations that include class and use. Check the actual report or declaration against the project’s required standard and use category. Do not assume two standards or differently described tests are interchangeable.
KEDA S300 Weatherproof Facade Silicone Sealant is intended for nonstructural weathersealing around facade and exterior joints. Request the movement evidence for the actual grade being offered. The example rating used here is not an S300 classification. Use the KEDA silicone sealant range to identify options by application, then confirm the technical requirements for the specific joint.

Illustrative material review. The cartridge and drawing do not represent an approved product, detail or test result.
ASTM C920's sealant classification and scope identifies movement class as one part of sealant classification. Ask for evidence for the proposed grade and check the project's expected opening and closing against the joint design.
5. Review the Joint Detail Before Ordering
A movement rating addresses only one part of selection. Check the permitted joint dimensions, compatible backing or bond breaker, intended bonding faces, and any surface preparation or primer requirements. Confirm both actual substrates, including coatings or stone treatments. If appearance matters on porous stone, review staining compatibility separately from movement capability.
Backing helps form the specified depth and avoid an unintended bond at the rear of the joint. A bead with the wrong profile or adhesion on a third surface can be restricted as the opening changes. Use the approved section rather than treating a movement class as permission to use any bead shape or fill the opening solid. Keep the weatherseal separate from structural attachment, drainage and other functions assigned to the facade assembly.
| Item to verify | What to request or record | If it is unresolved |
|---|---|---|
| Expected movement | Opening and closing demand, directions and installation assumptions | Obtain the project movement assessment |
| Width and depth | Measured range and approved section | Review locations outside the detail |
| Sealant capability | Exact grade, directional limits and supporting evidence | Keep technical selection pending |
| Materials and preparation | Substrates, finishes, backing, primer and trial requirements | Confirm compatibility on representative materials |
| Installation review | Agreed mockup, inspection points and acceptance criteria | Resolve the process before bulk installation |
The KEDA joint sealing and weatherproofing solution describes product selection by materials, geometry and exposure. When submitting an inquiry, include a section drawing with the intended bonding surfaces and the actual width range. The team can then discuss the joint itself rather than trying to infer the requirement from a facade photograph.
6. Turn the Review Into a Clear Handoff
Once the joint is reviewed, record the accepted grade and detail together. Show the crew which dimensions to check, which substrates need separate preparation, and who reviews out-of-range openings. Label the sample or mockup with the materials used. If a different finish, primer or sealant is substituted later, route that change back through the review.
Use a short joint schedule to carry the decision from the drawing to the order. Give each joint type an identifier and record its location, materials, width range, opening and closing demand, and accepted grade. A panel-to-panel weatherseal and a window perimeter can look similar in a photograph while having different service requirements. List them separately so the buyer does not combine two specifications into a single line item.
For purchasing, separate technical selection from quantity. Calculate how much material to order after the section and length are agreed. A change in width or depth can affect consumption, so a supplier quote based on a different joint size may need to be revised. Specify the actual grade and packaging rather than relying on an informal description such as “facade silicone, high movement.”
Carry the calculated requirement into the backer rod and joint geometry review.
Send the width survey, expected movement, detail and substrate samples or photos to KEDA’s product inquiry team. Overseas buyers can use the distributors and partners page to discuss samples and supply arrangements. Ask for the evidence and instructions that apply to the proposed grade before finalizing an order.
Perguntas frequentes
1. Does ±25% mean 25% total movement?
It describes up to 25% in each direction from the stated reference width in this example. A 12 mm reference gives 3 mm of opening and 3 mm of closing, considered separately. Check how the actual product documents its rating.
2. Can I calculate movement using the width shown on the drawing?
Use the reference agreed for the assessment and verify actual widths on site. A nominal drawing dimension can hide tight sections that experience a higher percentage change.
3. Is elongation at break the same as a movement rating?
No. Elongation at break comes from a tensile measurement. Movement evidence addresses a sealant’s ability to accommodate specified changes under the relevant test conditions.
4. Does a higher movement class fix an undersized joint?
Check the approved geometry and application limits independently of the rating. A higher movement capability cannot establish that the selected product can be installed correctly in the available opening.
5. Is the ±25% example a KEDA S300 rating?
No. The numbers explain how to interpret a hypothetical rating. Request product-specific movement evidence and review it against the actual joint and project specification.