KEDA · PU FOAMS

Window & Door PU Foam

Filling the Gap Around Installed Frames

KEDA Window & Door PU Foam is intended for frame-to-wall installation gaps in window and door projects. Its proposed role is gap filling within a complete installation detail, with product selection based on the frame, surrounding substrate and site conditions.

Ámbito de aplicación
Window and door frame-to-wall gaps
La selección comienza con
Frame material · gap dimensions · fixing details

Distributor enquiries & qualifying bulk orders

Descripción general del producto

01

Rellenado de separaciones en marcos

02

Window & door work

03

Complete installation

04

Selección de solicitudes

Información sobre el producto

Información sobre la selección de productos
Ámbito de aplicaciónWindow and door frame-to-wall gaps
Detalles de la selecciónFrame material · gap dimensions · fixing details
Requisitos del pedidoConfirma la calidad, el color, el embalaje y la cantidad suministrados

Solicita las instrucciones actuales del producto y las especificaciones de suministro confirmadas para tu aplicación.

Planning a bulk order?

Share your application, destination and expected quantity.

Solicitar un presupuesto

Selección de solicitudes

Solicitudes que se van a debatir

  • Perimeter gaps around mechanically secured window frames.
  • Installation gaps around fixed door frames before finishing.
  • Frame-to-opening gaps in replacement and renovation projects, after the existing installation has been assessed.

Confirm the actual product's suitability for the frame material, surface finish and joint dimensions. A general-purpose foam should not be assumed suitable for a pressure-sensitive frame.

Plan the Complete Installation

Foam filling does not replace the frame's required mechanical fixings, packers or supports. Follow the window or door manufacturer's installation detail.

Provide the specified internal air seal and external weather protection as part of the complete joint. Keep drainage paths, weep openings and operating clearances unobstructed. Foam alone is not a complete window waterproofing system.

GUÍA DE SOLICITUD

Empieza por la tarea de instalación o mantenimiento.

Revisa los materiales y la aplicación antes de elegir el grado suministrado.

Descubre nuestras soluciones

Flujo de trabajo de la solicitud

Guía general de solicitud

Use this overview with the instructions and safety information for the confirmed product; it does not define a fill ratio or curing schedule.

1. Check the frame and gap

Confirm alignment, fixing and support before filling. Check that gap dimensions, substrate condition and ambient conditions are within the product's permitted range. Do not inject foam into frame cavities unless the frame manufacturer specifically permits it.

2. Prepare and protect

Remove dust, loose material and contamination from the bonding surfaces. Protect nearby finishes and test representative materials. Lightly dampen surfaces only where the product instructions require it; do not apply over standing water or ice.

3. Apply with control

Use the specified compatible applicator. Follow the label for can preparation and orientation. Trial the output, then fill progressively, allowing for the actual foam's expansion. Follow the supplied instructions for wider or deeper gaps rather than filling the entire space at once.

4. Cure and finish

Keep the installation undisturbed for the specified curing period. Trim only when permitted, without damaging adjoining seals or frame finishes. Protect cured foam from sunlight and weather using the specified compatible finishing system. Check drainage and frame operation after completion.

Preguntas antes de realizar el pedido

How is this different from KD500 Multi-Purpose PU Foam?

The intended page focus is different: this product addresses frame-installation gaps, while KD500 covers general filling enquiries. Product names alone do not demonstrate different formulations or comparative performance. Confirm the actual product specification for the project.

Does low expansion mean low curing pressure?

No. Expansion describes a change in foam volume; curing pressure concerns the force exerted as foam cures in a constrained space. Evaluate both for pressure-sensitive frames. Neither property is claimed for this draft without supporting product information.

Can foam replace frame screws or anchors?

Do not use this product as a substitute for the mechanical fixings and supports required by the frame manufacturer and installation design.

Can I leave the cured foam exposed outdoors?

Provide the specified compatible protection from sunlight and weather. A filled gap does not replace the joint's required weatherseal or drainage detail.

Is it suitable for fire doors or fire-rated joints?

No fire-system suitability is established here. Such installations require a product and assembly specifically documented for the required application.

CONSULTA SOBRE PRODUCTOS DE KEDA

Discuss Your Window or Door Project

Send KEDA the frame material, surrounding substrate, gap dimensions and installation conditions. Include the intended applicator, destination market and estimated quantity. We will review the requirements and confirm available options before quotation.

KEDA Window & Door PU Foam