<trp-post-container data-trp-post-id='1319'>Epoxy Adhesive Mix Ratios: Weight vs. Volume for Stone Work

A 1:1 volume ratio is not an instruction to weigh equal amounts. Understand the measurement basis, choose a suitable dispensing method, and record each batch before mixing epoxy for stone work.

Par KEDAPublié Mise à jour
Editorial illustration of an empty bench scale and a separate vessel of epoxy paste on a marble surface.

An epoxy label says “A:B = 1:1,” so an operator weighs the same amount of each component. That procedure is correct only if the instructions specify a weight ratio. If the approved ratio is by volume, equal weights can give a different mixture.

For a stone workshop, the solution is a clear instruction that connects the supplied grade, component order, ratio, measurement basis and dispensing method. This guide explains the difference between weight and volume, how to avoid common measuring errors, and what to record before a batch reaches the workpiece.

1. Read the Whole Ratio, Including the Measurement Basis

A mixing ratio needs more than two numbers. Identify which component comes first, what each number represents and whether the quantities are measured by weight or volume. Follow the actual Part A and Part B designations rather than guessing their roles from color or container size.

“Parts” are proportional units. They can mean grams when the instruction is by weight, or a defined volume when it is by volume. The basis must stay consistent throughout the calculation and dispensing operation.

Instruction on the supplied productWhat it meansCorrect starting action
A : B = 1 : 1 en volumeEqual measured volumes of A and BUse the approved volumetric dispensing method
A:B = 1:1 by weightEqual measured masses of A and BUse a suitable scale and the approved weighing procedure
A:B = 100:30 by weight — illustrative exampleThirty weight parts B for every hundred weight parts ACalculate both amounts on the stated weight basis
A:B = 1:1 with no basis identifiedThe instruction is incomplete for choosing a measuring methodConfirm the basis for the exact grade before dispensing

Put the complete instruction on the workshop batch sheet. A large “1:1” sign with the words “by volume” missing is an avoidable source of confusion when operators or products change.

Editorial instruction-sheet illustration drawing attention to the words by volume beneath A and B.

Read the measurement basis with the ratio. The sheet is an editorial prop, not an actual product instruction.

2. See Why Equal Volumes Can Have Different Weights

Density relates mass to volume: mass = volume × density. If the two components have different densities, the same volume of each will have different weights.

Consider this hypothetical pair of materials. The values below are invented for arithmetic only; they are not KEDA component densities or a dosing instruction.

ComponentAssumed densityVolume in this exampleCalculated mass
Partie A1.60 g/mL100 mL160 g
Partie B1.20 g/mL100 mL120 g

The measured volume ratio is 1:1, while the corresponding mass ratio is 160:120, or 4:3. Weighing equal masses would not reproduce those equal volumes.

This example explains the distinction; it does not authorize a workshop conversion. For an actual adhesive, obtain the manufacturer’s approved alternative ratio and method. A density for the mixed adhesive cannot replace the separate component information needed for conversion.

Component densities can also happen to be equal or close. That possibility is not a reason to assume the same numbers apply on both bases. Use the published or confirmed instruction for the supplied grade.

3. Apply the Confirmed Basis to the KEDA Product

The current Adhésif époxy structurel à deux composants KEDA page specifies A:B = 1:1 by weight. Weigh the supplied Parts A and B in equal amounts on the same scale.

Use that weight basis for this product. Equal volumes can give different weights. If a label or instruction appears inconsistent, send KEDA the product name and component identifiers before mixing.

Keep this instruction separate from other products. The knife-grade polyester marble adhesive uses its own matching hardener and grade-specific dosing instructions. Epoxy slab adhesives and other repair systems also need their own instructions; an A/B label alone does not make their recipes interchangeable.

Correct proportioning is one part of the bonding process. For stone-cladding interfaces, product selection, preparation, contact geometry, supports and the installation design remain separate requirements.

4. Match the Measuring Method to a Thick Paste

For a volumetric instruction, use a suitable, verified dispensing method that can measure the actual material consistently. A liquid measuring cup may be easy to read with water but difficult to fill reliably with a non-flowing adhesive paste.

Check how the approved method deals with air pockets, filling level and transfer. A heaped scoop has an uncertain volume. A cavity beside the container wall occupies space without contributing adhesive. Material left on a transfer tool can also change the quantity that reaches the mixing vessel.

Do not treat two visually similar blobs on a board as measured equal volumes. If a workshop uses a fixed-volume device, establish its suitability and filling procedure with the supplier, then train operators to use it consistently. The same spatula does not automatically deliver the same volume on every scoop.

For a confirmed weight-based instruction, choose a scale suitable for the component amounts being dispensed. Check its condition, usable range and verification procedure. Display resolution alone does not establish weighing accuracy. Tare the appropriate vessel and identify whether the batch sheet shows each component’s separate amount or a cumulative target.

With an approved weighing method, make the display convention explicit. The cumulative display target after adding B includes the material already in the vessel; a separately tared B target does not. Mixing those conventions can produce an error even when the component amounts were calculated correctly. Label the fields “A added,” “B added” or “combined target” as appropriate, and keep the same convention across the instruction and record.

An accurate scale cannot correct the use of the wrong ratio basis. Equally, a correct volume ratio on paper cannot compensate for a measuring method that leaves unknown voids in a thick paste.

Editorial macro illustration of a paste-filled measuring vessel with a visible unfilled pocket near its wall.

Inspect how a thick paste occupies the measuring space. Illustration; the vessel and visible pocket do not define a dose or an approved measuring tool.

5. Plan Partial Batches Without Guessing the Quantities

Choose a batch size that can be measured reliably, mixed thoroughly and applied within the actual working conditions. Very small component amounts make handling losses and measurement errors more significant relative to the intended dose.

Distinguish the amount of Part A from the combined component charge. If an instruction sheet asks for a total batch amount, both component targets must be calculated from that total on the approved basis. If it starts with a known amount of Part A, calculate the required B from that amount instead.

For example, a hypothetical 1:1 weight instruction and a 200 g total component charge gives 100 g A plus 100 g B. A hypothetical 1:1 volume instruction and a 200 mL total component charge gives 100 mL A plus 100 mL B. These arithmetic examples are not recommended KEDA batch sizes, and the component-volume sum is not a specification for final cured volume.

Avoid the opposite mistake of mixing an entire delivery pack just because the containers came together. Packaging describes the supply configuration; it does not establish a suitable working batch. Larger confined quantities can build heat and shorten the available working period.

If the required batch is too small for the available equipment, obtain a workable dispensing method. Do not solve an equipment limitation by rounding one component to whatever is convenient.

6. Keep Accurate Dispensing and Thorough Mixing Separate

After the correct amounts are dispensed, they still need to be mixed properly. Keep clean, separate source tools for A and B so one component is not carried back into the other container. Use the specified mixing vessel and method for the supplied adhesive.

Work through the material deliberately, including the sides and bottom where required by the instructions. A uniform-looking color is useful to observe, but it cannot prove that every part of a paste batch has been mixed adequately. Follow the required mixing process rather than ending solely because the streaks disappear.

Record the mixing start and use the supplied definition of working time. Temperature, batch quantity and container conditions affect the process. Do not compensate for a rushed workflow by changing the A:B ratio, adding extra Part B, or introducing water or solvent.

Keep the source containers closed between dispensing operations. If the product requires preparation of an individual component before dispensing, follow that grade-specific method; do not automatically apply another resin’s stirring instructions to every paste.

Keep dispensing, mixing and application tools identifiable on the bench. A simple tool arrangement helps the next operator maintain the same process without relying on memory.

Overhead editorial illustration with separate Part A and Part B tool trays and a distinct mixing vessel.

Keep source tools separate and mix in the designated vessel. The arrangement does not represent a ratio, batch quantity or actual KEDA packaging.

7. Respond to a Measuring Error Before Using the Batch

If an error is noticed before A and B are combined, follow the approved dispensing procedure to establish the correct quantities in clean receiving vessels. Keep contaminated material out of the source containers. Record the correction so another operator can understand what changed.

Once components are mixed and the actual proportion is uncertain, keep that batch off the workpiece. Follow the supplier’s disposition instructions. Adding a guessed amount of one component to “balance” an unknown mixture creates another unknown rather than a controlled correction.

If an affected batch has already been applied, identify the bonded parts and pause further release or loading while the responsible reviewer assesses the situation. Record the product, estimated amounts, measuring method, mixing time and application locations. A hard surface does not establish that an off-ratio assembly meets its requirements.

When the batch sheet is correct but curing is abnormal, investigate component identity, transfer losses, mixing completeness, conditions and storage history. The stone adhesive selection guide helps keep product scope clear, while the bond-testing guide addresses evaluation of the actual interface.

8. Use a Batch Record That Another Operator Can Repeat

A useful record links the instruction to what was actually dispensed. Record the measurement basis beside every target quantity and keep units visible. Separate target values from actual values and any correction.

Batch-record fieldQue faut-il saisir ?
Product and componentsSupplied grade, Part A and B identifiers, and relevant batch references
Approved instructionA:B ratio, component order, weight or volume basis, and instruction version
Batch targetsSeparate A and B quantities with units; identify whether the total is a component charge
Equipment and methodMeasuring device, verification status, filling or taring method and transfer procedure
Actual dispensingAmount of each component and any recorded correction before mixing
Mixing and conditionsOperator, mixing start, method, batch conditions and observed working behavior
Workpiece linkParts or joints receiving the batch and the relevant inspection or release record

For distributor training, use one clearly identified product example at a time. Label generic arithmetic exercises as examples and keep them apart from approved customer instructions. A translated quick guide must retain “by weight” or “by volume,” not just the ratio numbers.

Through the KEDA distributor channel, discuss the selected grade and the information your customers need. To clarify a mixing instruction, contacter KEDA with label photographs, component identities, the intended dispensing method and the proposed batch size.

Foire aux questions

1. Does 1:1 epoxy always mean equal weights?

No. It means equal quantities on the stated measurement basis. A 1:1 volume instruction requires equal measured volumes; use equal weights only when the supplied product specifies that basis.

2. Can I use a scale for KEDA’s two-component structural epoxy?

Yes. For KEDA’s two-component structural epoxy, weigh Parts A and B separately on the same scale at a 1:1 weight ratio.

3. Are equal-size A and B containers a reliable measuring guide?

No. Container size and supply quantity do not establish the dose for a partial batch. Follow the product’s ratio, basis and approved dispensing method.

4. Can extra Part B make epoxy cure faster?

Keep the A:B ratio within the product instructions. Changing it is not a controlled way to adjust cure speed and can prevent the mixture developing the intended properties.

5. Is uniform color enough to show that epoxy is mixed correctly?

No. Color is one observation. Correct dispensing and a complete mixing method are both needed; uniform color alone does not verify the ratio or mixing completeness.

PARLONS DE VOS BESOINS

À la recherche de l'adhésif adapté
pour votre marché ?

Indiquez-nous les produits qui vous intéressent, leur application et la quantité souhaitée. Nous travaillons avec des distributeurs à l'étranger et fournissons les transformateurs et les entrepreneurs dont les commandes atteignent la quantité minimale requise.