If paint or powder coat stays on a metal part, the adhesive bonds to the coating. The coating must also remain bonded to the metal and be suitable for the exposure. Decide with the project team whether the coating is to stay or be removed before preparing the interface.
| Decision | Verify before bonding |
|---|---|
| Retain the coating | Coating type, cure, condition, attachment to metal and documented compatibility with the supplied adhesive |
| Remove only within a defined bond area | Approved removal limits, bare-metal preparation and the plan for corrosion protection at the boundary |
| Coating unknown or already lifting | Hold the work and identify the coating and failure before selecting a preparation |
Read the separation surface, then document the change
On an approved sample, determine whether the adhesive separated from the coating, the coating detached from the metal, or a layer fractured within itself. Photograph both faces and identify any coating transferred to the adhesive. If the failure location is ambiguous, retain the sample for review. A satisfactory test on bare metal does not validate a painted production part.
Record the retained or removed coating, preparation, approved sample, supplied adhesive grade and any change to the coating supplier or finish. Keep the assembly’s specified supports and fixings in place. For general metal selection use the stone-to-metal preparation guide by surface type. Send KEDA the coating details, backing and specified interface to discuss evidence for the proposed combination.