A window can have a filled installation gap and still need a perimeter seal. It can also have a neat visible sealant bead while the concealed gap, frame support or drainage detail needs attention.
PU foam and silicone sealant address different parts of the installation. Choose foam for a suitable gap-filling role and a specified sealant for the relevant nonstructural joint. Keep mechanical fixing, insulation, air sealing and weather protection clear in the installation plan.
For distributors, this distinction makes product recommendations more useful. For installers, it helps identify the information needed before choosing a can, cartridge or complete perimeter detail.
1. Name the Job Before Choosing the Product
Ask the customer to point to the location that needs work. Is it the space between the installed frame and wall opening, the finished connection between two surfaces, or a problem with how the frame is secured?
| Installation task | Product or system to discuss | What to establish |
|---|---|---|
| Fill a suitable frame-to-wall installation gap | Window and door PU foam | Frame sensitivity, gap dimensions, substrate and application conditions |
| Seal a nonstructural perimeter or finishing joint | Suitable silicone or another specified joint-sealing system | Both contact surfaces, joint design, movement and exposure |
| Secure and support the frame | Specified fixings, packers and supports | Window or door manufacturer’s installation requirements |
| Complete air and weather control | Designed seals, tapes, membranes or other specified components | Continuity with the surrounding construction and drainage detail |
A helpful customer description is “a frame-to-wall filling gap behind the reveal,” rather than simply “a window gap.” Likewise, identify whether a sealant bead connects the frame to render, trim, another coating or a different material.
This approach also prevents an unsuitable substitution. A larger quantity of one material does not automatically perform the separate job assigned to another installation component.
2. Gather the Frame and Joint Details
Use a photograph for orientation and a drawing or measurements for the concealed detail. Mark the location under discussion so the supplier can distinguish the installation cavity from the visible sealing joint.
| Information to collect | Why it helps selection |
|---|---|
| Frame material and finish | Identifies the actual surface and any pressure-sensitive frame concerns |
| Adjoining wall, coating or trim | Defines the second contact surface and preparation questions |
| Gap width, depth and access | Helps assess product suitability and application equipment |
| Frame fixing and support arrangement | Establishes the condition before filling begins |
| Interior or exterior location and exposure | Identifies the required sealing and protection discussion |
| Site and material conditions | Allows comparison with the product’s permitted application conditions |
| Proposed finishing and drainage detail | Shows what must remain accessible or unobstructed |
Record uncertainty explicitly. If the installer cannot see the gap depth behind an existing trim, identify that limitation rather than supplying a guessed dimension.
For replacement work, also describe the existing foam, sealant, coating and any reported leakage or operating problem. A surface repair may be only one part of the required work. Establish the condition and cause before selecting replacement material.
3. Use Window Foam for the Suitable Filling Role
KEDA Window & Door PU Foam is presented for suitable frame-to-wall installation gaps. Select the actual grade against the frame, substrate, gap and conditions, within the complete installation detail.
Confirm the frame’s mechanical fixing, alignment and support before filling. Keep the required packers and supports in place according to the frame manufacturer’s instructions. The product enquiry should identify any frame that could be sensitive to curing pressure.
Expansion and curing pressure are separate selection questions. Ask for relevant information for the proposed product and frame instead of treating a “low-expansion” description as proof that every frame is suitable.
Before a production job, obtain the supplied product’s preparation, dispensing and curing instructions. These should resolve the permitted conditions, application method and treatment of the actual gap. Use a representative trial to establish how the selected configuration works for the installer.
Plan finishing access at the same time as filling. The person applying foam should know which surfaces will later receive a seal, which components must remain clear and when the next operation is permitted.

Unfinished material mockup illustrating a filling location. It does not show the complete fixing, sealing or weather-protection detail.
4. Use Silicone for the Specified Nonstructural Joint
KEDA S200 Door & Window Neutral Silicone Sealant is intended for nonstructural window and door sealing. Identify the surfaces on both sides, including their coatings, before discussing the product for a particular perimeter joint.
The sealant selection needs more than a preferred color. Establish the joint width and depth, expected movement, exposure and required preparation. Follow the selected joint design for backing material and primer where specified.
Keep the sealing surfaces sound and prepared using a method compatible with the actual materials. Include adhesion and compatibility checks in the sample plan, particularly when coatings or adjoining finishes differ from those previously used.
A neat bead is a finishing observation, not a complete assessment of the joint. Record its contact with the intended surfaces, continuity and curing conditions alongside the relevant performance checks.
Separate perimeter sealing from structural attachment of glass. A request involving structural glazing, a special glass assembly or a sensitive adjoining material needs the appropriate product and system assessment. “Neutral silicone” alone does not define every possible application.

Editorial surface detail; not a verified S200 application, movement rating or complete joint design.
5. Coordinate Filling, Sealing and Finishing
Turn the approved installation detail into a sequence the team can follow. Identify the work that must be inspected before it becomes concealed, then assign responsibility for the next operation.
Before filling, check the frame position and specified fixing arrangement. Before sealing, check the intended contact surfaces and the joint preparation. Before trims or finishes hide the connection, review the required continuity and access points.
Some tapes, membranes or related components may need installation earlier in the sequence. Follow the actual system detail instead of assuming every job follows “foam first, silicone last.” Agree how adjacent materials interact and what preparation is required between stages.
Use permitted curing stages to plan the handover. Record when material was applied and when trimming, covering, tooling or another operation is allowed. A surface appearance alone is not a universal timing rule.
For example, if foam has expanded into the area reserved for a perimeter joint, pause and restore the specified detail through the approved method. Applying a thin sealant smear over whatever surface remains does not demonstrate that the designed joint has been formed.
6. Keep Protection and Drainage in the Discussion
Plan how the filling material will be protected after curing. Soudal’s published filling guidance calls for protection from sunlight and weather and completion of the required seals and fixings. Apply the actual KEDA product and project instructions to the selected installation.
Likewise, treat the interior air seal and exterior weather detail as identified tasks. Soudal’s window-system literature illustrates the industry distinction between inner sealing, middle insulation and outer weather protection. This helps explain the roles; it does not establish that an arbitrary combination of products forms a tested system.
Preserve specified drainage paths, weep openings and operating clearances. Ask the frame manufacturer to identify them where necessary. A visible opening near the frame is not automatically an unwanted gap to fill.
If a window leaks, record when water appears, the weather conditions and the apparent entry location. Review the frame, surrounding construction and drainage arrangement before deciding that another bead or more foam is the remedy.
For a broader joint sealing and weatherproofing enquiry, identify the complete connection and exposure. Keep the product recommendation tied to that detail.
7. Match the Applicator to the Supplied Foam Format
KEDA’s window and door installation range presents KD600 in 750 ml gun-grade and manual straw-applied formats, alongside S200 in a 300 ml cartridge. Confirm the order configuration and compatible equipment for the supplied version.
Discuss how the customer works: available access, frequency of use, operator familiarity and the equipment already in the workshop or on site. Select the applicator format deliberately rather than ordering by can capacity alone.
For either foam format, obtain instructions for preparation, orientation, output control and interruptions. Include the approved equipment-cleaning and storage arrangements in the work plan. Different valves or adapters should not be treated as interchangeable without confirmation.
For sealant, select equipment and nozzle preparation suited to the intended bead and product instructions. A foam dispensing gun and a cartridge caulking gun are different tools with different roles.
Keep the requested quantities separated by product and format in the quotation. This makes delivery checks easier and reduces the chance that the installer receives the right product name in the wrong application configuration.

Generic demonstration accessories illustrate format choices; they are not a list of approved KEDA-compatible tools.
8. Evaluate a Representative Installation Detail
Before a bulk purchase or changed application, agree a trial that represents the frame finish, adjoining material and relevant geometry. Define what the trial should demonstrate and who will review it.
| Trial or inspection stage | What to record | Decision supported |
|---|---|---|
| Starting condition | Materials, dimensions, frame alignment and specified supports | Whether the proposed detail is ready for the trial |
| Foam application | Product version, applicator, conditions and observed control | Whether the filling configuration suits the workflow |
| Permitted next stage | Actual timing, material condition and frame operation | Whether to proceed under the supplied instructions |
| Sealant preparation and application | Contact surfaces, preparation, joint geometry and bead continuity | Whether the proposed sealing detail can be executed consistently |
| Completed detail | Required inspections or project tests and recorded observations | Whether the agreed application requirements are met |
Give each trial an identifier and retain the product labels, batch references, operator notes and photographs. Photograph the connection before it is concealed. If a product, frame coating or finishing component changes, record the change and review the relevant part of the trial rather than carrying the earlier acceptance forward automatically.
Keep observations precise. “Frame operated normally at the recorded inspection stage” is more useful than an unsupported promise of zero curing pressure. Similarly, describe the actual sealing check instead of writing “fully waterproof” after a visual inspection.
Agree any required air, water or movement assessment separately, with the relevant method and responsible reviewer. A workshop mockup can help evaluate workmanship and compatibility; its appearance does not establish the performance of every installed window.
9. Build a Clear Distributor Recommendation
Organize the offer around customer tasks: frame-gap filling, nonstructural perimeter sealing and the information needed to select each. Show the available formats and supporting instructions with the correct product identity.
For distributors and partners, a useful recommendation includes the confirmed product configuration, the customer’s application brief and the remaining questions before use. A combined commercial offer should still identify the separate roles and any additional specified installation components.
For a quotation discussion, send KEDA the installation details: frame and adjoining materials, gap or joint dimensions, photographs, exposure, preferred foam format, sealant color, quantity and destination. Include required technical or project documentation.
Keep thermal, acoustic, fire and weather-performance claims linked to relevant product and assembly evidence. Can size, a finished-looking bead or the presence of foam does not provide those results.
Preguntas frecuentes
1. Can PU foam replace the window frame’s anchors?
Retain the specified mechanical fixings, packers and supports. Select foam for its suitable filling role within the frame manufacturer’s installation detail.
2. Does a foam-filled gap make the whole window waterproof?
Complete the specified weather protection, perimeter seals and drainage detail. Review the complete installation and any required assessment; a filled cavity alone does not establish that result.
3. Can silicone always be applied directly over cured foam?
Follow the approved joint design. Confirm the sealant’s intended contact surfaces, backing arrangement and material compatibility. Do not assume a thin coating over exposed foam forms the required joint.
4. Does low expansion mean the foam cannot distort a frame?
Ask about curing pressure and suitability for the actual frame as separate questions. Evaluate the selected product and installation conditions without treating a general expansion description as a guarantee.
5. Should I choose gun foam or straw foam?
Choose the confirmed format for access, work pattern and compatible equipment. Check the actual dispensing and interruption instructions, then trial the configuration before committing to routine use.